logo
Found 951 results for "

data center ups

"
Qualidade Visench 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA 3 fases UPS online para Data Center fábrica

Visench 60KVA 80KVA 100KVA 120KVA 180KVA 200KVA 240KVA 300KVA 3 fases UPS online para Data Center

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

Qualidade 10KVA-40KVA Capacidade nominal Visench Galleon ll 3 Phase Tower UPS para Data Center fábrica

10KVA-40KVA Capacidade nominal Visench Galleon ll 3 Phase Tower UPS para Data Center

MODEL10K(L)15K(L)20K(L)30KL40KLPHASE3-phase in/3-phase outCAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KV /40KWINPUTHominsl Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC (Ph-N)Voltage Range138~270 VAC(3-phase)@50%load;173~253 VAC(3-phase)@100%load 80~156 VAC(Ph-N) 50%load;100~148 VAC(Ph-N)@100%loadFrequency Range46~54 Hz or 56~64HzPower Factor≥0.99 @100%LoadOUTPUTQuput Voltage3x208/220 VAC(Ph-Ph) 3x120/127 VAC(Ph-N)AC Voltage Regulation (Batt.Mode)±1%Frequency Range

Qualidade 30KVA 30KW 30000W 30000VA Pure Sine Wave Online Ups para Data Center Visench Galleon III fábrica

30KVA 30KW 30000W 30000VA Pure Sine Wave Online Ups para Data Center Visench Galleon III

Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion≤ 2% THD (Linear Load) ;≤ 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40°CSize(mm

Qualidade 60KW 3 Fases OEM Visench Fortress 3p3p 60K Peso Kgs 94/169/249/360 UPS para Data Center fábrica

60KW 3 Fases OEM Visench Fortress 3p3p 60K Peso Kgs 94/169/249/360 UPS para Data Center

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

Qualidade 3 Fase IP20 120KVA 120KW 120000W 120000VA Visench Fortress Online Ups para Data Center fábrica

3 Fase IP20 120KVA 120KW 120000W 120000VA Visench Fortress Online Ups para Data Center

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

Qualidade 240KVA 3 Fases Visench Fortress 3p3p 240KW OEM Fornecimento de energia On-line Ups para Data Center fábrica

240KVA 3 Fases Visench Fortress 3p3p 240KW OEM Fornecimento de energia On-line Ups para Data Center

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

Qualidade Data Center Visench Galleon III 3 Fase Pure Sine Wave OEM UPS Capacidade nominal 10KVA-40KVA fábrica

Data Center Visench Galleon III 3 Fase Pure Sine Wave OEM UPS Capacidade nominal 10KVA-40KVA

Product nameGalleon III 3p3pRated Capacity10KVA-40KVAPower Factor0.99Input Voltage3 x 360/380/400/415 VAC(3Ph+N)Frequency40~70 HZOutput Voltage3 x 360*1380*/400/415 VAC (3Ph+N)WaveformPure Sine waveBattery Type12V/9AhPHASE3Ph in/ 3Ph out or 3Ph in 1Ph out or 1Ph in 1Ph outHarmonic Distortion≤ 2% THD (Linear Load) ;≤ 5 % THD (Non-inear Load)Current Crest Ratio3:1(max.)Battery Mode94.50%Frequency Range46~54Hz or 56~64HzInverter to BypassZeroOperating Temperature0-40°CSize(mm

Qualidade 7.5KVA 7.5KW 7500W 7500VA UPS digital industrial de baixa frequência de fase única para data center fábrica

7.5KVA 7.5KW 7500W 7500VA UPS digital industrial de baixa frequência de fase única para data center

MODELGiant Elite 6k(L)Giant Elite 7.5k(L)Giant Elite 10k(L)PHASESingle phase with groundCAPACITY6KVA/4.8KW7.5KVA/6KW10KVA/8KWINPUTNominal Voltage208VAC/220VAC/230VACVoltage Range165VAC~285VAC @16 pcs of batteries;185VAC~285VAC @18 pcs of batteriesFrequenc40 Hz~55 Hz @50Hz system;56 Hz~64 Hz @60Hz systemOUTPUTOutout Voltage208VAC/220VAC/230VACVoltage Regulation±1%Frequency Range (Synchronized Range)45Hz~55 Hz or 56 Hz~64 HzFrequency Range (Batt.Mode)50 Hz±0.1 Hz or 60Hz±0.1

Qualidade Vertiv liebert CRV CW 30KW 60KW Tipo de precisão Ar condicionado Centro de dados Sistema de arrefecimento para centro de dados fábrica

Vertiv liebert CRV CW 30KW 60KW Tipo de precisão Ar condicionado Centro de dados Sistema de arrefecimento para centro de dados

Product Description Specification itemvalueApplicable IndustriesManufacturing PlantConditionNewTypePrecision Industrial Air ConditionerPlace of OriginChinaGuangdongBrand NameVertiv liebertOperating Voltage380/400 VACMountingFloor StandingWarranty1 YearDimension(L*W*H)300*1100*2000 600*1100*2000 mmKey Selling PointsHigh Safety LevelAirflow5900 11000 12200 m³/hMachinery Test ReportProvidedVideo outgoing-inspectionProvidedWarranty of core components1 YearCore ComponentsPressure